The operating conditions and main technical data are as follows:
1. Operating conditions:
Atmospheric Temperature: 25âÂÂÂÂÂÂÂÂ
Atmospheric Pressure: 1010mbar
Humidity: 80%
Fuel: 180cst HFO
2. Gas turbine data:
Model: GT13D3A
Compression Grade: 18
Turbine Grade: 5
Pressure Ratio: 12.4
Air Flow: 317kg/s
Turbine Inlet Temperature: 990âÂÂÂÂÂÂÂÂ
Turbine Exhaust Temperature: 500âÂÂÂÂÂÂÂÂ
Combustor: Single-cylinder, Single injector
3. Operating data (Standard Status and Basic Load)
Output power of each turbine: 92MW
Total output power by combined cycle: 273MW
Unicycle Fuel consumption: 296g/kWh
Unicycle Heat efficiency: 29.8%
Combined cycle Fuel consumption: 204g/kWh
Combined cycle Heat efficiency: 43%
Combined cycle Total Heat consumption: 8376KJ/kWh
4. Steam turbine main data:
Model: DK1—1N31 Single-cylinder, Straight condensing, Reaction turbine
Grade Number: 26
Inlet Steam Pressure: 36bar
Inlet Steam Temperature: 473âÂÂÂÂÂÂÂÂ
Exhaust Steam Pressure: 0.065bar
Rated Power: 87MW
5. The Overhaul of generating set:
Under the terms of manufacturer- ALSTOM, when use HFO fuel, the overhaul cycle of GT13D3A gas turbine is 16000EOH, GT13DM gas turbine: 24000EOH, steam turbine: 50000EOH.
Want to know more about it, pls don't hesitate to contact with us by MSN:sztwt at hotmail dot com or you can send email to above address.